Mech Flash Charger / 机械族闪充站 [Beta]
О материале
«Mech Flash Charger / 机械族闪充站 [Beta]» — материал мастерской RimWorld. Моды для колонии: новые возможности, предметы и удобство игры. Для установки откройте оригинал в Steam Workshop, проверьте требования автора и подпишитесь. Совместимость с версией игры редакцией не проверена.
Описание автора
V1 Beta · Requires the Biotech DLC · RimWorld 1.6 [From the archive] Our team dug up an old high-power charging sketch beneath the ice and adapted it for mechanoids on the rim. At room temperature, one light Lifter went from 4.96% to 97% in about 8.4 game hours. Such is the joy of archaeology. This project employs no engineers. Conception, planning, implementation, balance numbers, art and the text on this page were all produced by AI — none of it was designed or hand-made by a human. The only human contribution was pressing the upload button and accepting Steam's agreement. Personnel is still debating what grade of protective equipment a workshop with a headcount of zero should receive. This is a beta. Single-station charging, the temperature curve, power loss and save loading have been played. 50-station performance, medium and ultraheavy mechanoids, multi-mech charger contention and sealed-room heat have not been tested — see the end of this page.
What it adds
Two late-game mechanoid charging buildings sharing one continuous charge curve, with thermal management, dynamic grid demand and waste heat. Everything runs on vanilla mechanics: vanilla charging AI, reservations, power-loss interruption, waste container, and the berserk reaction when a charger is destroyed mid-charge are all preserved. Implemented as the vanilla charger class plus a ThingComp — no Harmony patches and no edits to vanilla defs. The inspect panel shows status, mechanoid, energy, instantaneous rate, time to 50/90/97/100%, power demand, ambient temperature and thermal efficiency.
Light vs. large
-
Mech flash charger: 3×1, light mechanoids only; 3,200 W peak grid demand; steel 180, plasteel 40, component industrial 4, component spacer 2; 190 HP; waste container 5.
-
Large mech flash charger: 3×2, medium / heavy / ultraheavy; 4,800 W peak; steel 320, plasteel 80, component industrial 6, component spacer 4; requires Construction 7; 300 HP; waste container 10.
Both idle at 80 W and use the same curve. The large station's higher draw pays for heavier mechanoids and the cooling they need — it does not charge faster.
Tapering at high charge
The curve is defined as "percent of full capacity per game hour": 7.5%/h at 0%, 9.5%/h at 10%, 13%/h at 50%, a 14%/h peak at 70%, 9.5%/h at 90%, 4.5%/h at 97%, and 0.2%/h approaching 100%. Nodes are linearly interpolated, so the rate is continuous with no jumps. Above 97% the panel reads "trickle charging" and grid demand falls to roughly 100–200 W. Vanilla work modes can set an auto-charge exit threshold, so a mechanoid does not always stay until 100%; departure follows vanilla behaviour.
Cold preheating and heat derating
Thermal efficiency: 100% from 10–40°C; 97% at 0°C; 94% at −10°C; 88% at −20°C; 82% at −30°C; 70% at −50°C. Above 40°C it falls off: 85% at 50°C, 60% at 60°C, 35% at 70°C, bottoming out at an 8% floor at 100°C. At 50°C and above the panel shows thermal throttling. Below −10°C a mechanoid preheats on arrival: about 0.75 game hours at −30°C and about 1.5 game hours at −50°C. While preheating, the grid draws 55% of rated peak and the mechanoid gains almost no energy. All multipliers are interpolated continuously, so nothing oscillates on an on/off switch.
Dynamic grid load and waste heat
Demand is calculated from current SOC and ambient temperature each tick; grid power output is updated every 30 ticks or when demand changes by more than 10% of peak. When supply is short, vanilla power logic sheds the load as usual; the station never charges out of thin air. Heat is pushed into the environment at 2.5 heat/s (2.0 heat/s while preheating), scaled by current demand. A vanilla heater is 3.5 heat/s, for scale. Waste heat may warm a cold room; the temperature rise in a sealed room has not been measured yet. Toxic waste follows the vanilla formula and is settled on energy actually delivered, so pollution for a given state-of-charge band is intended to match vanilla (5 wastepacks per full-capacity recharge baseline). Only the formula-level check is done; a side-by-side wastepack count against the vanilla charger has not been performed.
Dependencies and research
-
Required: RimWorld 1.6 and the Biotech DLC (hard dependency). No Harmony; no other mod's files are overwritten; only this mod's two buildings are affected.
-
New research "mech flash charging": prerequisite "high mechtech", cost 2400, requires a mechanitor, done at a hi-tech research bench with a multi-analyzer. Both stations unlock behind it.
Languages
English and Simplified Chinese: building names, descriptions and all inspect strings are localized.
What has been tested
In-game measurements (single Lifter, single light flash charger, fixed ambient temperature, sampled every 0.1 game hours, starting energy about 4.2–5%):
-
25°C: 4.96% → 97% in 8.4 game hours (about 10.6 h to 100%); peak 3,194.9 W, mean 2,088.3 W.
-
−30°C: 4.18% → 97% in 11.0 game hours, including roughly 0.7–0.75 h of preheating (about 13.7 h to 100%); peak 2,634.6 W.
-
60°C: 4.65% → 97% in 14.1 game hours (about 17.8 h to 100%); peak 1,949.0 W.
These full curves are from one Lifter on one station. A heavy tunneler had only a short charging test; other mechanoids, temperatures and power setups lack comparable full-run data — please do not extrapolate. Other verified items:
-
Automatic AI: a Lifter pathfinds in and leaves when charged; a heavy tunneler taken over by a mechanitor entered the large station and charged.
-
Power test: with only a 1,000 W chemfuel generator the station did not charge at multi-kW demand (about 13 game hours, energy 4.2% → 2.9%) and resumed automatically once supply returned.
-
Destroying a charger mid-charge produced the vanilla berserk message and event.
-
Saves: saved at 51.1% while charging and reloaded in the same process — charging continued (a full game restart was not tested).
-
Compatibility: all official DLC plus this mod started and loaded a save; the pre-existing 199-mod list plus this mod reached the map and completed one Lifter charge. The full mod list also produced unrelated third-party errors (RimHUD disabled itself; a WVC JobGiver called a missing vanilla API). No stack contains this mod's code, but the log is not error-free, so this is not a "fully compatible" claim.
Known limitations
-
This build is a V1 beta, not a stable release. No 50-station performance test has been run; please do not quote any 50-station figures.
-
The full curve was measured on one light Lifter; the heavy tunneler entered the large station once; medium and ultraheavy mechanoids have not been verified in game.
-
Not yet tested: multiple mechanoids contending for a station and reservations, multi-station setups, ordinary deconstruction, sealed-room heat build-up, a side-by-side pollution comparison with the vanilla charger, four-facing / snow / damaged art, multiplayer.
-
The mod reads one private vanilla field to correct waste accounting. If a future update renames it, the station logs an explicit error and falls back to the vanilla charging speed rather than silently changing pollution.
-
Common mods not installed here (multiplayer mods, RimThreaded, RocketMan, Combat Extended, Performance Fish, etc.) carry no compatibility promise.
-
When a mechanoid leaves is decided by vanilla behaviour (work modes can set a threshold), so charging to 100% is not guaranteed.
Как установить и запустить
Откройте оригинальную страницу в Steam Workshop, проверьте версию игры, зависимости и порядок загрузки в описании автора. Нажмите «Подписаться» и дождитесь загрузки Steam. Включите материал в меню модификаций или контента игры, если это требуется. Совместимость и запуск редакцией не проверены.